( Brand: Hamilton ), ( Manufacturer Part Number: 809018 ), ( Part Type: Star Heater Shaker )
The Hamilton 809018 Heater Shaker is a versatile and essential accessory for laboratories using robotic pipetting workstations, such as the Star Line series. This heater shaker is designed to ensure optimal temperature control and gentle agitation for various biochemical reactions and assays.
The device features an ergonomic design with a compact footprint, allowing it to fit seamlessly into any lab setup. It accommodates up to 14 microplates of standard size (178 x 122 mm) or 9 deep-well plates (128 x 85 mm), depending on the user's requirements.
Each plate position comes with an independent temperature control, allowing users to maintain precise temperature settings between 4 C and 65 C (39.2 F and 149 F) to accommodate a wide range of applications. The temperature is accurately monitored and maintained using a PID (Proportional-Integral-Derivative) controller, ensuring consistent and reliable results.
The Hamilton 809018 Heater Shaker offers both orbital and linear agitation modes to cater to different application needs. The orbital agitation mode provides a gentle shaking motion, while the linear mode offers a back-and-forth motion, both with adjustable speed settings. This agitation helps to maintain even temperature distribution and ensures proper mixing of reagents and samples during incubation.
This heater shaker also comes equipped with various safety features, including a tilting and automatic shut-off function to prevent sample spillage and overheating. Additionally, the device includes an intuitive touchscreen interface, making it easy to set up, operate, and monitor temperature and agitation conditions.
The Hamilton 809018 Heater Shaker is a valuable addition to any robotic pipetting workstation setup, offering precise temperature control, gentle agitation, and a compact design, all while ensuring efficient and accurate results for a wide range of applications.
The Hamilton 809018 Heater Shaker is a popular accessory for the Star Line robotic pipetting workstations. This device is designed to ensure proper temperature control and agitation for various applications, including enzyme assays, ELISA assays, and cell culture. In this discussion, we will explore the key benefits and potential drawbacks of investing in the Hamilton 809018 Heater Shaker for your Star Line robotic pipetting workstation.
Pros:1. Temperature Control: The heater shaker offers precise temperature control, ensuring consistent results for your assays. This is crucial for maintaining the optimal environment for enzymatic reactions and cell cultures.
2. Agitation: The heater shaker provides gentle agitation, which is essential for ensuring even mixing of reagents and maintaining homogeneous samples. This is particularly important for applications such as ELISA assays and cell cultures, where uniform sample composition is critical.
3. Compatibility: The Hamilton 809018 Heater Shaker is designed to be fully compatible with the Star Line robotic pipetting workstation, allowing for seamless integration into your laboratory workflow.
4. Versatility: The device is suitable for use with various types of microplates, from 96-well to 384-well formats, making it a versatile addition to your laboratory equipment.
5. Improved Efficiency: By automating the heating and agitation process, the heater shaker can save valuable time and resources compared to manual methods.
Cons:1. Cost: The Hamilton 809018 Heater Shaker can be a significant investment, especially for smaller laboratories or research groups with limited budgets.
2. Size: The device takes up a considerable amount of bench space, which may be a concern for laboratories with limited space.
3. Maintenance: The heater shaker requires regular maintenance to ensure optimal performance, which can include cleaning and calibration.
4. Power Consumption: The heater shaker consumes a significant amount of power, which can lead to increased energy costs over time.
Conclusion:The Hamilton 809018 Heater Shaker is an excellent investment for laboratories that require precise temperature control and gentle agitation for their Star Line robotic pipetting workstation applications. Its compatibility, versatility, and efficiency make it a valuable addition to any laboratory setting. However, potential drawbacks such as cost, size, maintenance requirements, and power consumption should be carefully considered before making a purchase. Ultimately, the decision to invest in the Hamilton 809018 Heater Shaker depends on the specific needs and resources of your laboratory.
Recommendation:If your laboratory routinely performs assays or applications that require precise temperature control and gentle agitation, such as ELISA assays, enzyme assays, or cell cultures, the Hamilton 809018 Heater Shaker is a worthwhile investment. The benefits it offers in terms of temperature control, agitation, compatibility, versatility, and efficiency can significantly enhance your laboratory workflow and improve the consistency and accuracy of your results. However, if your laboratory has limited resources and space or performs a relatively small volume of temperature-sensitive assays, it may be more cost-effective to explore alternative methods or invest in lower-cost equipment.
From Laboratory Surplus. Item is new and in original manufacture packaging.